Improving measurement accuracy of composite non-point sources emissions based on laser detection
CSTR:
Author:
Affiliation:

1.Key Laboratory of Environmental Optics& Technology, Anhui Institute of Optics and Fine Mechanics, the Chinese Academy of Sciences, Hefei, 230031, China;2.Anhui Agricultural University, Hefei, 230061, China;3.Hefei University of Technology, Hefei 230009, China

Clc Number:

O43

Fund Project:

Supported by the National Natural Science Foundation of China (41805124); Chinese Academy of Sciences Scientific Research Instrument and Equipment Development Project(YJKYYQ20190051) Key Research and Development Plan of Anhui Province (201904a07020093); Anhui Natural Science Foundation Project (1808085MD107).National Engineering Laboratory of Advanced Technology and Equipment for Atmospheric Pollution Monitoring(2005DP173065-2021-04)

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    In the measurement of source emissions, it is inevitably interfered by the gas emissions from the adjacent fields and turbulence, which affects the accuracy of gas detection. In order to improve the measurement accuracy, the measurement method of composite non-point sources non-uniformity methane emissions based on laser spectrum detection has been studied. Moreover, the interference in external environment is reduced with multiple self-calibration measurements. A detection system for composite non-point source emissions has been established, and the detection method of eliminating gas fluctuation has been proposed. First, the accuracy verification test has been carried out. The standard deviation of source a is 0.17, and that of source b is 0.18. Subsequently, a comparative test has been carried out with the extraction method of the photo acoustic spectrum, and the correlation coefficient reached 0.91. Finally, the actual field measurement has been carried out to monitor the two non-uniform emission sources caused by different fertilization methods to achieve accurate measurement. It has practical engineering value such as agricultural gas emission and environmental gas detection.

    Reference
    Related
    Cited by
Get Citation

TANG Qi-Xing, ZHANG Yu-Jun, HE Ying, WANG Li-Ming, LI Meng-Qi, YOU Kun, LI Xiao-Yi, CHEN Dong, LIU Wen-Qing. Improving measurement accuracy of composite non-point sources emissions based on laser detection[J]. Journal of Infrared and Millimeter Waves,2021,40(3):363~368

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:July 18,2020
  • Revised:April 29,2021
  • Adopted:August 24,2020
  • Online: April 27,2021
  • Published: June 25,2021
Article QR Code